產(chǎn)品展示
聯(lián)系我們
聯(lián)系人:麥女士
手機(jī):+86 15270269218
電話:
Q Q:3136378118
郵箱:stodcdcs@gmail.com
地址:江西省九江市瑞昌市東益路23號賽湖農(nóng)商城401號
VT3014-S37-R5
11 X16編程接口(COM)12 X10串行接口(PROG)13用于接地的插入螺栓14 X7E以太網(wǎng)接口(可選)圖12-1:PPC-R22.1 PPC-R是一種IP 20設(shè)計的小尺寸大容量控制器。PPC-R是一個通用平臺,提供運(yùn)動控制(MC)或PLC功能,這取決于應(yīng)用程序和軟件。根據(jù)Indra‐mat標(biāo)準(zhǔn)(SIS=串行Indramat接口),控件上的兩個可用接口完全連接。數(shù)據(jù)類型傳輸(功能)僅由應(yīng)用程序(RS232/RS422/RS485)選擇。由一個或多個RMB02.2-04組成的模塊托架系統(tǒng)用于安裝PPC\R。雙托架RMB02.2-02只能用作安裝托架。載體只能用于固定PPC-R,無法控制RECO模塊。也不可能通過背板耦合多個PPC-R。PPC-R多可操作15個以上的輸入/輸出模塊(RME02.2…、RMA02.2…或RMC02.2…)在這個載體系統(tǒng)中。根據(jù)應(yīng)用情況,PPC-R配有PC/104模塊,例如用于開放式現(xiàn)場總線接口,如Interbus、Profibus等。12.2操作和錯誤顯示符號,LED顯示屏描述測量以太網(wǎng)上的LED H3 LED激活(發(fā)送和接收活動)以太網(wǎng)鏈路有效-LED關(guān)閉以太網(wǎng)未激活檢查以太網(wǎng)連接H1-四個數(shù)字診斷顯示屏的相關(guān)性取決于配置-圖12-1:前面板上用于操作和錯誤顯示的LED 13錯誤原因和消除典型應(yīng)用錯誤安裝情況未知。14維護(hù)控制裝置免維護(hù)。



11 X16 programming interface (COM) 12 X10 serial interface (PROG) 13 Insert bolt for ground connection 14 X7E Ethernet interface (optional) Fig.12-1: PPC-R22.1 The PPC-R is a small size high-capacity control in IP 20 design. The PPC-R is a universal platform that provides Motion Control (MC) or PLC functionality that depend‐ ing on the application and software. The two interfaces available on the control are fully connected according to the Indra‐ mat standard (SIS = Serial Indramat Interface). The data type transfer (function) is only selected by the application (RS232/RS422/RS485). A module carrier system consisting of one or several RMB02.2-04 are used to mount the PPC_R. The dual carrier RMB02.2-02 can only be used as mounting carrier. The carrier can only be used to fix the PPC-R, controlling RECO modules is not possible. It is also not possible to couple several PPC-R via a back plane. The PPC-R can operate up to 15 more I/O modules (RME02.2..., RMA02.2... or RMC02.2...) in this carrier system. Depending on the application, the PPC-R is equipped with PC/104 modules, e.g. for open field bus interfaces such as Interbus, Profibus etc. 12.2 Operating and Error Display Symbol, LED Display Description Measure LED H3 LED on Ethernet active (sending and receiving activity) The Ethernet link is valid - LED off Ethernet not active Check Ethernet connection H1 - The relevance of the four-dig‐ it diagnostic display depends on the configuration - Fig.12-1: LED for operating and error display on the front panel 13 Error Causes and Elimination Typical application errors upon the installation are not known. 14 Maintenance The control is maintenance-free.
相關(guān)產(chǎn)品